Self-developed all-in-one pre-processing system enables automated nucleic acid extraction → library construction → library concentration detection→ library pooling, realizing true pre-processing automation. It simplifies the most complex and tedious step
Product Features
Integrates extraction, library construction and quality control modules, enabling fully automated operation of the entire process. It also can be used in extraction+QC or library pre+QC modes alone, reducing labor and operation time.
Adopts an integrated design, integrating functional modules as needed to meet customized needs.
Supports flexible full-process handling of 1–32 samples, meeting library preparation needs across varying sample throughputs.
Equipped with physical door locks and sensors to ensure operator safety. Features a comprehensive anti-contamination design, including UV disinfection lamps and HEPA filtration systems, providing multi-layered protection for both samples and personnel.
Automates the entire process to avoid manual errors.
The pipetting module uses pressure - based liquid level detection to enable microliter precision pipetting.
Offers multiple full - process library construction programs and graphical software operations for quickly configuring library construction schemes.
The software process displays in real-time, allowing you to check the current operation steps and th countdown to completion.
Performs power-on self-test and error alarm to ensure the smooth progress of experiments.
Specifications
Used to ensure sample safety, equipped with a high-efficiency filter and UV disinfection system. It also features a contamination-prevention air duct to achieve full-process contamination control.
Adopts magnetic bead-based nucleic acid extraction. It can process 1–32 samples in one run, with a single-sample volume capacity of 50–6000 µL.
Used for nucleic acid concentration detection, employing air displacement method. It supports a concentration range of 0.1–120 ng/µL.
Equipped with low-temperature cooling function to maintain the stability of reagent enzyme activity. Temperature range: 4–8 °C.
Built-in heating function (ambient temperature to 90°C) with an oscillation speed of 0–2500 r/min, enabling efficient reagent mixing.
Adopts a circumferential magnetic frame to eliminate edge magnetic force attenuation is integrated with a spring buffer device to ensure the positioning accuracy of the well plate.
Used for PCR amplification during library preparation, featuring automatic sealed lidding (no manual intervention required) and eliminating the need for external control equipment. The PCR module offers a temperature range of 4–99 °C with a temperature accuracy of ±0.3 °C.
Adopts air displacement principle, with 32-channel precision-controlled liquid handling. Liquid transfer range: 2–200 µL.

Registration Certificate No.: Yue Xie Zhu Zhun 20252220901
Technical Document